CAD/BIM CATALOG CAD (0) ▾ Cart is empty Request CAD files All Categories > ACR Copper Press Fittings ACR Copper Press Fittings Request Information ACR Copper Press Fittings acr Elbows 02---RP02734.png Couplings 01---RP10146-.png Reducers 04---RP01035.png Tees 06---RP04031.png Flare Adapters 07---RP15729.png Caps 05---RP07009.png CYCLEMASTER® Ball Valves - FTG X FTG (8) Features: Design Pressure (DP) / Maximum abnormal pressure (MAP): 775 psig, 53 bar Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C Contact factory or visit website for compatibility with CFC, HCFC, HFC and HFO refrigerants and oils Full port construction to match line size ID Internally equalized ball design Rupture-proof encapsulated stem MCM Seal Technology UL/cUL Listed, Conforms to Pressure Equipment Directive 2014/68/EU, CRN 0C1241.9C CYCLEMASTER_-Ball-Valves---FTG-X-FTG.JPG CYCLEMASTER®FTG x FTG Multi Split Ball Valve with Access Port (8) Available in sizes 1/4” – 1-3/8” Available with insulation (select sizes) Operating Temperature: -40°F – 300°F / -40°C – 149°C Full port construction to match line size ID Internally equalized ball design Rupture-proof encapsulated stem MCM Seal Technology Certifications: UL/cUL Listed Conforms to Pressure Equipment Directive 2014/68/EU CRN 0C1241.9C FTG-X-FTG-MULTI-SPLIT-BALL-VALVE.png DRYMASTER® FTG X FTG Filter Driers (5) Configurations Available: O.D.: 3/8” and 1/2” Liquid Line or Heat Pump 8 or 16 Cubic Inches Operating Temperature: -40°F – 160°F/ -40°C – 70°C Solid core design High pressure shell and connections High retention filter for removal of particulate as small as 25 microns Certifications: UL/cUL Listed Conforms to EU Pressure Equipment Directive and UK Pressure Equipment Regulation Filter-Driers.png Hermetically Sealed FTG X FTG Sight Glass/Moisture Indicator (7) Available in sizes 1/4” to 1-1/8” Operating Temperature: -40°F – 185°F / -40°C – 85°C Designed for maximum flow and minimum pressure drop Large viewing window and indicator for better visibility Provides accurate identification of system conditions Certifications: UL/cUL Recognized Conforms to EU Pressure Equipment Directive and UK Pressure Equipment Regulation Moisture Content PPM: REFRIGERANT75°F LIQUID REFRIGERANT 100°F LIQUID REFRIGERANT   Green/Dry Yellow/WetGreen/Dry Yellow/Wet R-323012545185 R-134A2511045175 R-404A207525130 R-407C3014555230 R-410A2516545300 R-507A157530140 HERMETICALLY-SEALED-FTG-X-FTG-SIGHT-GLASS.png Required Fields * Email * Project Name Project Location First Name * Last Name * Job Title Company * Business/Industry * Component Manufacturer Contractor Distributor Engineering Firm OEM Other Wholesaler Zip/Postal Code * State * AK AL AR AZ CA CO CT DE FL GA HI IA ID IL IN KS KY LA MA MD ME MI MN MO MS MT NC ND NE NH NJ NM No Preference NV NY OH OK OR PA RI SC SD TN TX UT VA VT WA WI WV WY Country * AFGHANISTANAland IslandsALBANIAALGERIAAMERICAN SAMOAANDORRAANGOLAANGUILLAANTARCTICAANTIGUA AND BARBUDAARGENTINAARMENIAARUBAAUSTRALIAAUSTRIAAZERBAIJANBAHAMASBAHRAINBANGLADESHBARBADOSBELARUSBELGIUMBELIZEBENINBERMUDABHUTANBOLIVIABOSNIA AND HERZEGOWINABOTSWANABOUVET ISLANDBRAZILBRITISH INDIAN OCEAN TER.BRUNEI DARUSSALAMBULGARIABURKINA FASOBURUNDICAMBODIACAMEROONCANADACAPE VERDECAYMAN ISLANDSCENTRAL AFRICAN REPUBLICCHADCHILECHINACHRISTMAS ISLANDCOCOS (KEELING) ISLANDSCOLOMBIACOMOROSCONGOCOOK ISLANDSCOSTA RICACOTE D'IVOIRECROATIACUBACYPRUSCZECH REPUBLICDEMO. PEOPLE'S REP. KOREADemocratic Republic of CongoDENMARKDJIBOUTIDOMINICADOMINICAN REPUBLICECUADOREGYPTEL SALVADOREQUATORIAL GUINEAERITREAESTONIAETHIOPIAFAEROE ISLANDSFALKLAND ISLANDSFED. STATES MICRONESIAFIJIFINLANDFRANCEFRENCH GUIANAFRENCH POLYNESIAFRENCH SOUTHERN TER.GABONGAMBIAGEORGIAGERMANYGHANAGIBRALTARGREECEGREENLANDGRENADAGUADELOUPEGUAMGUATEMALAGuernseyGUINEAGUINEA-BISSAUGUYANAHAITIHEARD AND MC DONALD ISL.HONDURASHONG KONGHUNGARYICELANDINDIAINDONESIAIRANIRAQIRELANDIsle of ManISRAELITALYJAMAICAJAPANJerseyJORDANKAZAKHSTANKENYAKIRIBATIKUWAITKYRGYZSTANLAOSLATVIALEBANONLESOTHOLIBERIALIBYAN ARAB JAMAHIRIYALIECHTENSTEINLITHUANIALUXEMBOURGMACAOMACEDONIAMADAGASCARMALAWIMALAYSIAMALDIVESMALIMALTAMARSHALL ISLANDSMARTINIQUEMAURITANIAMAURITIUSMAYOTTEMEXICOMONACOMONGOLIAMontenegroMONTSERRATMOROCCOMOZAMBIQUEMYANMARNAMIBIANAURUNEPALNETHERLANDSNETHERLANDS ANTILLESNEW CALEDONIANEW ZEALANDNICARAGUANIGERNIGERIANIUENORFOLK ISLANDNORTHERN MARIANA ISL.NORWAYNOT ON THE LISTOMANPAKISTANPALAUPalestinian TerritoryPANAMAPAPUA NEW GUINEAPARAGUAYPERUPHILIPPINESPITCAIRNPOLANDPORTUGALPUERTO RICOQATARREPUBLIC OF KOREAREPUBLIC OF MOLDOVAREUNIONROMANIARUSSIAN FEDERATIONRWANDASaint BarthelemySAINT KITTS AND NEVISSAINT LUCIASaint MartinSAINT VINCENT & GRNDNSSAMOASAN MARINOSAO TOME AND PRINCIPESAUDI ARABIASENEGALSerbiaSEYCHELLESSIERRA LEONESINGAPORESLOVAKIASLOVENIASO. GA & SO. SNDWCH ISL.SOLOMON ISLANDSSOMALIASOUTH AFRICASPAINSRI LANKAST. HELENAST. PIERRE AND MIQUELONSUDANSURINAMESVALBARD & JAN MAYEN ISL.SWAZILANDSWEDENSWITZERLANDSYRIAN ARAB REPUBLICTAIWANTAJIKISTANTHAILANDTimor-LesteTOGOTOKELAUTONGATRINIDAD AND TOBAGOTUNISIATURKEYTURKMENISTANTURKS & CAICOS ISLANDSTUVALUUGANDAUKRAINEUNITED ARAB EMIRATESUNITED KINGDOMUNITED REP. OF TANZANIAUnited States Minor Outlying IslandsUNITED STATES OF AMERICAURUGUAYUZBEKISTANVANUATUVATICAN CITYVENEZUELAVIETNAMVIRGIN ISLANDS (BRITISH)VIRGIN ISLANDS (U.S.A.)WALLIS & FUTUNA ISLANDSWESTERN SOMOAYEMENZAMBIAZIMBABWE Phone Number Submit