Features:
  • Design Pressure (DP) / Maximum abnormal pressure (MAP): 2031 psi, 140 bar
  • Continuous operating temperature (COT): -40°F/300°F, -40°C/149°C
  • Designed for transcritical CO2 systems
  • Bi-directional flow
  • Brass body with copper-iron alloy connections
  • Bleed hole in ball allows for the support of gas pressure without stressing other components
  • Full port construction to match line size
  • Rupture-proof, internally-loaded stem
  • Specially selected o-ring material compatible for CO2 operating conditions
  • UL/cUL Listed, conforms to Pressure Equipment Directive 2014/68/EU and EN 378‐2, CRN 0C1241.9C
CYCLEMASTER® Ball Valves - Transcritical CO2